SPEC 44 Mounting Wire from TE Connectivity RAYCHEM

SPEC 44 mounting wire from TE Connectivity RAYCHEM is used in demanding applications where high performance, reliability, and durability are required. This cable is designed and manufactured to the highest standards, including AS-81044, NEMA-WC-27500, and VG95218, and is commonly used in aerospace, defense, transportation, and other demanding industrial applications. Most cables in the SPEC 44 series come with NATO Stock numbers.

SPEC 44 cable from TE Connectivity Raychem is made from high-quality materials that withstand high temperatures, corrosion, chemicals, and mechanical stresses. The cable features an insulated sheath that meets the strictest safety and performance requirements, providing protection against short circuits and other electrical faults.

SPEC 44 mounting cable from TE Connectivity Raychem is available in various sizes, colors, and lengths, and can be supplied on reels or in pre-cut lengths. It is also available in different conductor types, including solid, stranded, and braided, and can be provided with various insulation materials such as PVC, polyurethane, and fluoropolymer.

SPEC 44 cable from TE Connectivity Raychem offers excellent performance in demanding environments. It can withstand high temperatures up to 150 degrees Celsius, making it suitable for use in applications with extreme temperatures and thermal shocks. It also provides high resistance to chemicals, making it ideal for use in the petrochemical industry and other industrial applications.

Additionally, SPEC 44 cable from TE Connectivity Raychem offers outstanding electrical performance, including low resistance, minimal crosstalk, and high signal integrity. This makes it ideal for use in applications such as communication networks, control and automation systems, and in the electronics and telecommunications industries.

spec44-240×280

Features of the RAYCHEM SPEC44 Mounting Cable:

  • Dual wall construction.
  • Voltage range 600, 1000, and 2500V
  • Compact and lightweight.
  • Resistant to most chemicals and following electrical arcs.
  • Temperature range of -65…+150°C.

Product Categories SPEC 44 Mounting Wire

And click through to view color options for these products.

Artikelnummer

Temperatuur klasse

Constructie

Draad klasse

Aantal aders

Type ader

AWG formaat

Formaat in mm2

44A0111-30 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 30 0.05mm2
44A0111-28 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 28 0.08mm2
44A0111-26 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 26 0.14mm2
44A0111-24 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 24 0.25mm2
44A0111-22 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 22 0.34mm2
44A0111-20 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 20 0.50mm2
44A0111-18 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 18 0.75mm2
44A0111-16 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 16 1.5mm2
44A0111-14 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 14 2.5mm2
44A0111-12 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 12 4.0mm2
44A0111-10 150°C ( XL-PVF mantel) Primaire draad 600V 1 Vertind koper 10 6.0mm2
44A0112-28 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 28 0.08mm2
44A0112-26 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 26 0.14mm2
44A0112-24 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 24 0.25mm2
44A0112-22 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 22 0.34mm2
44A0112-20 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 20 0.50mm2
44A0112-18 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 18 0.75mm2
44A0112-16 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 16 1.5mm2
44A0112-14 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 14 2.5mm2
44A0112-12 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoat koper 12 4.0mm2
44A0114-30 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoate koperlegering 30 0.05mm2
44A0114-28 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoate koperlegering 28 0.08mm2
44A0114-26 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoate koperlegering 26 0.14mm2
44A0114-24 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoate koperlegering 24 0.25mm2
44A0114-22 150°C ( XL-PVF mantel) Primaire draad 600V 1 Zilver gecoate koperlegering 22 0.34mm2

Article Number

Temperature Class

Construction

Wire Class

Number of Conductors

Conductor Type

AWG Size

Size in mm²

44A0211-28 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 28 0.08mm²
44A0211-26 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 26 0.14mm²
44A0211-24 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 24 0.25mm²
44A0211-22 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 22 0.34mm²
44A0211-20 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 20 0.50mm²
44A0211-18 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 18 0.75mm²
44A0211-16 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 16 1.50mm²
44A0211-14 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 14 2.50mm²
44A0211-12 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 12 4.0mm²
44A0211-10 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 10 6.0mm²
44A0211-8 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 8 10.0mm²
44A0211-6 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 6 16.0mm²
44A0211-4 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Tin-plated Copper 4 25.0mm²
44A0212-26 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Silver-coated Copper Alloy 26 0.14mm²
44A0212-24 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Silver-coated Copper Alloy 24 0.25mm²
44A0212-20 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Silver-coated Copper Alloy 20 0.50mm²
44A0212-18 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Silver-coated Copper Alloy 18 0.75mm²
44A0212-12 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Silver-coated Copper Alloy 12 4.0mm²
44A0212-10 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Silver-coated Copper Alloy 10 6.0mm²
44A0212-8 150°C (XL-PVF cable sheath) Primary Wire 1000V, general use 1 Silver-coated Copper Alloy 8 10.0mm²

Article Number

Temperature Class

Construction

Wire Class

Number of Conductors

Conductor Type

AWG Size

Size in mm2

44A0311-28 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 28 0.08mm2
44A0311-26 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 26 0.14mm2
44A0311-24 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 24 0.25mm2
44A0311-22 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 22 0.34mm2
44A0311-20 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 20 0.50mm2
44A0311-18 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 18 0.75mm2
44A0311-16 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 16 1.50mm2
44A0311-14 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 14 2.50mm2
44A0311-12 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 12 4.0mm2
44A0311-10 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 10 6.0mm2
44A0311-8 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 8 10.0mm2
44A0311-6 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 6 16.0mm2
44A0311-4 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 4 25.0mm2
44A0311-2 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 2 35mm2
44A0311-0 150°C (XL-PVF cable sheath) Primary Wire 2500V, general use 1 Tin-plated copper 0 50mm2

 

Typical Properties

Operating Temperature -65…+150°C
Voltage Class (Thin Wall) 600V
Voltage Class (Thick Wall) 2500V
Tensile Strength and Insulation Elongation 28 N/mm², (4000 PSI), 230%
Shrinkage, 300°C <1%
Notch Propagation, 0.05 mm Notch Approved
Solder Resistance (370°C, 1 minute) Approved
Resistance to Fuels, Oils, Solvents Approved

Fire Performance

Flammability Federal Aviation Reg FAR-25 Approved
BS EN 50265 Vertical Flammability Approved
S424 14751 (Swedish chimney) Approved
NFC 32070 (2) (French chimney) Approved
IEC 60332 part 3 (cable ladder) Approved
Smoke/Toxicity Index Smoke index, Def Stan 61-12 (18) 6 per meter of cable
Toxicity index, Def 61-12 (18) 0.8 per meter of cable
BS EN ISO 4589 part 2 30% Oxygen
BS EN ISO 4589 part 3 30% Oxygen
Temperature index >300°C
SPEC 44 ordersysteem




Temperature Class


SPEC 44 wire and cable is suitable for continuous use from -65 °C to +150 °C and for short periods at temperatures up to 300 °C. Heat aging tests are routinely conducted at temperatures of 200°C (168 hours) and 300 °C (6 hours). Additionally, SPEC 44 insulation does not shrink back.

Mechanical Properties

SPEC 44 wiring provides better resistance to cutting compared to other cables with much thicker insulation. The 600 volt mounting wire 44A0111 (0.19 mm wall) offers 40% more resistance to cutting than other 600 volt PTFE insulated cables (0.25 mm wall).

Chemical Resistance and Low Outgassing

The irradiated dual-wall construction of SPEC 44 wire is highly resistant to acids, alkalis, hydrocarbons, solvents, fuels, lubricants, water, and many rocket propellants and oxidizers. The radiation crosslinking of SPEC 44 prevents the cold flow of the insulation, which is a recognized issue with some un-crosslinked materials.

For use in space applications, there are special low-smoke versions of SPEC 44 cables available, designed for environments with high vacuum and high temperatures.

Soldering Resistance

Thanks to the radiation cross-linking of the materials used in SPEC 44, it does not melt at high temperatures. As a result, SPEC 44 wire is resistant to prolonged contact with soldering irons.

EPD kabel van TE Connectivity Raychem

TE Connectivity RAYCHEM:

  • AS-81044, NEMA-WC-27500

  • Def Stan. 61-12 Part 18 – Type 1 pliable( maintenance range)

  • Def Stan. 61-12 Part 26 all types

  • VG 95218 part 20, 21, 22, 23 & 1000

  • NATO Stock Numbers exist for most standard cables.

  • Civil Aviation Authority accessory Approval E11623

  • TE Specification 44

Our Markets

The applicability of SPEC44 cable and the benefits it offers are almost universally applicable across every market. Here’s an overview:

Automotive

Automotive

Bouw en infrastructuur

Construction & Infrastructure

Defensie & Militaire mobiliteit

Defense & Military Mobility

Elektro- & Installatietechniek

Electrical & Installation Technology

Energie & Utiliteit

Energy & Utilities

Industriële machines

Industrial Machinery

Luchtvaart

Aerospace

Olie & Gas

Olie & Gas

Scheepvaart en voor de kust

Shipping and Offshore

Spoorwegen

Railways

Truck, Bus & Offroad voertuigen

Trucks, Buses & Off-Road Vehicles

Kastenbouw

Enclosure Construction

About Idétrading Electronics

Idétrading Electronics is an independent, advisory, service-oriented, and stocking distributor of a wide range of high-quality electrical materials, including products from TE Connectivity Raychem. Our product range caters to clients in various sectors, including installation, automotive, industry, process industry, petrochemicals, aerospace, defense, energy technology, MRO (Maintenance, Repair, and Operations), offshore, (semi-)government, and wholesale.

TE Connectivity RAYCHEM distributor